Tuesday, 27 September 2016

Role of SMF Battery in your UPS

Sealed Maintenance Free battery is the one that is completely sealed and thus adding of water is not required. It has the electrolyte which is in the form f gel that fills the cavity of the plates.
 
SMF batteries are preferred over lead batteries as the later emit harmful fuels when charged up thus polluting the environment and harming health. So SMF batteries have replaced the lead batteries in UPS. With complete seal, these batteries are highly suitable for inverters as they are not only safe but also require zero maintenance.  

It is most apt battery for your UPS as it is crafted to offer reliable, consistent and low maintenance power for UPS applications. Also in places where there are heavy load shedding this batteries are most efficient as they are prone to deep cycle applications.
 
In case the pressure inside increases then it has vent valve that opens up to release the gas. The main aspect is that the battery is pollution free; it is gaining wide popularity in the market. The lead calcium present in the battery epitomizes its long lasting nature and higher efficiency for low self discharge rate.
 
It is compact battery that occupies less space and thus can be fitted anywhere. It has following vitals aspects that makes it stand apart and ahead from other batteries: 
  • It requires zero maintenance and thus the headache of maintaining the batteries is done away with SMF batteries.
  • It has multi position usage and has the ability to resist explosion, in a way is safe and risk free while usage.
  • It is compact and there are no chances of any leakage or spilling.
  • This battery can withstand different ambient temperatures and operate perfectly and thus it is best option in case of electric fluctuations.
  • It has high discharge rate capacity.
  •  It does not generate corrosive or harmful gas and thus it is environment and health friendly.
  • They take less charging time as compared to other batteries.
  • Free from orientation constraints as the battery is sealed, it can be installed in any position – horizontal, vertical, sideways without having any effect on the performance.
  • SMF batteries emit no gas or fumes, it can be placed near the UPS system or any other electric equipment without any danger of eruption and also this allows minimal voltage drop between battery and equipment.
  • It has low self discharge
  • As this battery has very low internal resistance and high electrolyte, the active material reactive interface allows maximum currents for short and medium duration.
  • Usage of this battery saves umpteen numbers of liters of distilled waters 
  • UPS can be put to use immediately as there is no delay between receipt and use.
  • Also it is easy to install and does not require any specially trained man power for installation and commissioning procedures.

SMF batteries are thus boon for UPS as they are not only health friendly but also reliable, consume low electricity and have long shelf life.

Saturday, 27 February 2016

5 Warning Signs of Your UPS Battery Demise

UPS Battery Suppliers

UPS or the uninterruptible power supply is an electrical apparatus that renders emergency power supply to the load in case there is power failure. This device allows the computer to keep running for at least a short time when there is sudden loss of primary power source. Also it renders protection from power surges. As UPS provides consistent power supply to the computer it can also be referred to as battery backup or uninterruptible power source. However there are chances that UPS battery demises suddenly. 

Following are 5 warning signs of the UPS battery demise. 
  1. Low battery alarm: All the UPS have low battery alarm and they will run a periodic self test. UPS will give alert signal as to when there should be battery replacement is required. Usually they flash an indicator light or make an alarm sound. Also one gets alert mail if one has monitoring daemon set up.
  2. Symptoms: Batteries that are about to demise will generate symptoms that mimic Inverter failures or wonky control electronics. Signals like repeating alarms and flashing of panel lights etc indicate the demise of UPS battery. Also when your terminal displays white slag then it is the symptom of demise of UPS battery.
  3. Age: If your battery is 3-4 yrs old then it is high time that you need to replace it and this is vital sign that your UPS battery will demise in near future due to age. 
  4. End of useful life: End of useful life of battery is the point when the battery can no longer supply 80% of its rated capacity in ampere hours i.e. when the battery reaches 80% of its rated capacity, the aging process accelerates and the battery needs to be replaced.
  5. Early discharge: When your UPS battery takes long time to charge and when it gets discharged early then it is the sign that the UPS battery is going to get demise soon.  For More Info Visits - Trontek Batteries Importer.